TALOS EDGE alarm handler
Every alarm, in a crew member's hand.
TALOS EDGE takes alarms from the vessel's own systems and puts them on the crew's TETRA radios as call-outs they accept. If nobody accepts, it escalates until someone does — and it records every alarm, every send and who answered. It is the lightweight member of the TALOS family, built for a vessel with a small number of alarms: it runs on its own industrial edge controller, a compact DIN-rail unit, so it needs no ship's PC. For an unlimited number of alarms, the ship's phones and network text, Modbus, OPC, SNMP and webhook inputs, see TALOS CORE.
Alarms from the Systems Already Aboard
TALOS EDGE reads its own contact inputs and serial RS-232 and RS-485 lines.
Wi-Fi crew call buttons raise their calls on it directly, so guest calls and machinery alarms are handled by one system and land on the same radios.
A Call-Out the Crew Member Accepts
Each alarm reaches the radio as a TCCA Call-Out: the handset alerts until a crew member accepts it with one press, and the name of whoever accepted is recorded and shown. It works with DAMM TetraFlex TETRA systems.
For an incident, a muster call-out moves every radio it reaches onto an incident talkgroup the moment it lands, so the team is on one channel without anyone changing it by hand.
It Goes Further Until Someone Answers
Every alarm has its own escalation: if nobody accepts in time, it moves to the next stage — another crew member, a department, a group — and keeps going until someone does. An alarm is never left waiting for a person who is not there.
It Does Not Go Quiet
If the radio link drops, alarms raised meanwhile are held and sent the moment it returns, rather than lost. The unit watches its own health too, and reports a fault of its own to a radio rather than failing silently.
CE and UKCA Marked, with a Lifetime Hardware Warranty
TALOS EDGE is CE and UKCA marked, and its hardware carries a lifetime warranty.
A Record of Everything
Every alarm, every send, every escalation and every acceptance is recorded, and can be viewed and exported from the browser dashboard on the ship's network over HTTPS. Backups of the record are taken automatically. A wall display shows the ship's alarm state without needing an account.
See TALOS EDGE
Fire, blackout, tank and bilge alarms raised on the unit's own inputs, sent straight to the crew's radios as a TCCA call-out.
See It Working
Everything is set up and watched from a browser on the ship's network. These screens are from a demonstration vessel.
TALOS EDGE or TALOS CORE?
Both put the vessel's alarms on the crew's radios and keep going until someone accepts. TALOS EDGE is the lightweight, standalone unit: its own industrial edge controller, so it needs no ship's PC. TALOS CORE runs on a PC on the ship's network and adds everything else — the ship's phones, network text, Modbus, OPC, SNMP and webhook inputs.
| Feature | TALOS EDGE | TALOS CORE |
|---|---|---|
| Alarms to TETRA radios as call-outs the crew accept | ✓ | ✓ |
| Unlimited number of alarms (EDGE suits a small number) | — | ✓ |
| Escalation until someone accepts | ✓ | ✓ |
| Muster call-outs onto an incident talkgroup | ✓ | ✓ |
| Alarms held and sent when the radio link returns | ✓ | ✓ |
| Serial RS-232 and RS-485 inputs | ✓ | ✓ |
| Reading rules on measured values | — | ✓ |
| Wi-Fi crew call buttons | ✓ | ✓ |
| Full alarm record, HTTPS dashboard and backups | ✓ | ✓ |
| Own hardware with contact inputs, CE and UKCA marked | ✓ | — |
| Runs on its own industrial edge controller, no ship's PC needed | ✓ | — |
| Redundancy on a replicating virtual machine cluster | — | ✓ |
| Phone calls and texts through the ship's PABX | — | ✓ |
| Press 1 to accept on any phone, ACCEPT key on desk phones | — | ✓ |
| Network text inputs | — | ✓ |
| Modbus TCP/RTU alarm inputs | — | ✓ |
| OPC UA and OPC DA alarm inputs | — | ✓ |
| SNMP trap input | — | ✓ |
| Webhook input | — | ✓ |
TALOS EDGE — common questions
Its own contact inputs, serial RS-232 and RS-485 lines, and Wi-Fi crew call buttons.
TALOS EDGE is the lightweight, standalone unit for a small number of alarms: it runs on its own DIN-rail industrial edge controller with built-in contact inputs, is CE and UKCA marked, and needs no ship's PC. TALOS CORE runs on a PC on the ship's network, has no limit on the number of alarms, and adds phone calls and texts through the ship's phone system, plus network text, Modbus, OPC, SNMP trap and webhook inputs.
A limited number: TALOS EDGE is built for a vessel with a small number of alarms. For more alarms than that, TALOS CORE has no limit.
No ship's PC is needed. TALOS EDGE runs on its own industrial edge controller, a compact DIN-rail unit, and is set up and monitored from a browser on the ship's network.
It escalates through that alarm's stages — another crew member, a department or a group — until someone accepts. Every step is recorded.
Alarms raised while the link is down are held and sent as soon as it returns, and the unit reports its own faults rather than failing silently.
Yes. TALOS EDGE carries both the CE and the UKCA mark.
A lifetime hardware warranty.
DAMM TetraFlex. OLAS is the only DAMM Authorised System Partner in the superyacht industry.
Yes. Every alarm, send, escalation and acceptance is recorded, and can be viewed and exported from the browser dashboard.
We're here to help.
Talk to one of our specialist team about TALOS EDGE alarm handler. Call us, email us, or send a message with the form and we will reply as quickly as possible.